1. Sensor at center
2. Sensor at right edge
3. Reference point (point 0 on the platen's scale)
10.
Press the air injection connector against the air injection port on the roll shaft of the
feeding unit to inject air.
1
1. Air injection connector
(A) shows the cross-section of the roll shaft before injecting air. After injecting air, visually check
that the roll core clamps have extended and come in contact with the inside of the roll core, as
shown in (B). Then, turn the roll media by hand to check that the roll does not slip on the shaft.
(A)
1
1
M563IC0128
(B)
1
2
3
1185 mm
41 mm
2
3
2
3
M563IC0040
Setting Media
M563IC0148