Hitachi MP-WU8101W User Manual page 134

Hide thumbs Also See for MP-WU8101W:
Table of Contents

Advertisement

Regarding the indicator lamps
Regarding the indicator lamps (continued)
Indicator Status
Blinking In Red 1 time
Blinking In Red 2 ~ 6 times
Blinking In Red 1 ~ 5 times
Red
Blinking In Red 1 time
Red
(continued on next page)
The internal temperature is rising.
Turn the power off, and allow the projector to cool
Green
Red
down at least 20 minutes. After having confirmed the
following items, turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 45°C?
The interior portion has become heated.
Turn the power off, and allow the projector to cool
down at least 20 minutes. After the projector has
sufficiently cooled down, confirm the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
Red
Red
• Is the air filter dirty?
• Does the peripheral temperature exceed 45°C?
• Is the setting for ALTITUDE appropriate?
• Is the exhaust air (hot/cold) from peripheral
equipments blowing against the ventilation opening
of projector?
For details on ALTITUDE, refer to ALTITUDE of
SERVICE in the OPTION menu. If the projector is
used with a wrong setting, it may cause damage to
the projector itself or the parts inside.
Red or
All or part of light sources are not lighting.
Green
Turn off the projector and unplug the power cord, and
then turn on the projector again.
Red
Lens unit is not installed.
Make sure that the lens unit is installed correctly, and
turn on the projector again.
Description
13 4
QM00971-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp-wu8101b

Table of Contents