Setting Parameters

8-8-5 Positive and Negative Software Limits

1, 2, 3...
2. The pulse rate numerator is not changed here, so press either the Down (¯)
Key or the Return Key. Move the cursor to the pulse rate denominator value.
<C200H-MC221>
1
1
3. Enter the pulse rate denominator value (100 in this example). After the cor-
rect setting has been made, return to the Machine Parameter Edit screen.
Note If the pulse rate is set to a value greater than 1, it will not be possible to return to
the Machine Parameter Edit screen by pressing the Return Key. If this situation
occurs, reset the pulse rate and then try again.
1. Select "J:Negative Software Limit" from the Machine Parameter Edit
screen.
<C200H-MC221>
(---399999.99 to 399999.99)
2. Enter the negative software limit (for this example, enter "--50") and then
press the Return Key.
<C200H-MC221>
(---399999.99 to 399999.99)
3. Enter the positive software limit (for this example, enter "600") and then
press the Return Key.
Pulse Rate
Software Limits
---39999999 mm
mm
Software Limits
---50 mm
---39999999 mm
Section 8-8
X Machine Specs
0.01
mm
2048
X Machine Specs
0.01
mm
2048
X Machine Specs
0.01
mm
2048
77