Software Specifications - Omron SYSMAC CS Series Operation Manual

Loop control boards, process-control cpu units, loop controller, loop-control cpu units
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Specifications
1-3-5

Software Specifications

CX-Process Tool Specifications
Item
Product name
Model
Applicable PLC-series
Applicable Unit
Applicable computer Computer
Operating system
(OS) (See note.)
Japanese or English
Processor
Memory
Hard disk
Monitor
Disk device
Connecting method
Connection with
CPU Unit (or Serial
Communications
Board/Unit)
Connection via Con-
troller Link
Connection via
Ethernet
60
The following software (sold separately) is required to use the
• CX-Process Tool: Tool for preparing function block data (essential)
CX-Process Tool (included with CX-One)
CS1D-CPU@@P: CX-Process Tool (version 3.1 or higher)
CJ1G-CPU@@P: CX-Process Tool (version 4.0 or higher)
CX-Process Tool Version 5.2 or higher is required to use all functions of
LCB01/03/05 Version 3.5.
WS02-LCTC1EV3 (Ver. 5.0)
CS/CJ-series
Loop Control Unit, Loop Control Board, Process-control CPU Unit, or Loop-
control CPU Unit
IBM PC/AT or compatible
Windows XP (Service Pack 3 or higher), Windows Vista, or Windows 7
A processor that is recommended by Microsoft Corporation
The memory that is recommended by Microsoft Corporation
A minimum of approx. 2.8 GB is required to install all of the CX-One soft-
ware.
XGA (1,024×768) and 16-bit high color or better
CD-ROM driver or DVD-ROM drive
Using the FinsGateway Serial Unit Driver
Communications protocol with PLC: Host Link (not supported on Peripheral
bus)
The computer is connected to the CPU Unit peripheral port or built-in RS-
232C port, or RS-232C port of the Serial Communications Unit/Board.
- Connector cable: When connecting to the CPU Unit peripheral ports:
Model CS1W-CN@@@ (2 m, 6 m)
When connecting to the CPU Unit's RS-232C port: Model XW2Z-@@@-@
(2 m, 5 m)
(For details on model numbers, see 2-3 Connecting to CX-Process Tool.)
Using the CX-Server
Communications protocol with PLC: Host Link or peripheral bus
Using the FinsGateway CLK (PCI) Driver
The Driver is installed on the computer on which the PCI Controller Link
Support Board is mounted to enable communications with the PLC on
which the Controller Link Unit is mounted.
Using the FinsGateway Controller Link Driver or the CX-Server
The Driver is installed on the computer on which the ISA Controller Link
Support Board is mounted to enable communications with the PLC on
which the Controller Link Unit is mounted.
Using the FinsGateway ETH_UNIT Driver or the CX-Server
The Driver is installed on the computer on which the Ethernet Board is
mounted to enable communications with the PLC on which the Ethernet
Unit is mounted.
Specification
Section 1-3
:
Loop Controller