9.2 Operation at Over Limit Input
■
Operation at over limit input
Operations depend on the status of over limit input (+) and over limit input (-) as follows.
Condition
JOG positioning operation
is started
During JOG positioning
operation
■
Input valid logic of over limit input
● When the over limit switches (+) (-) are not connected to the pulse output unit, change the
input valid logic of the over limit switch to "NO contact". The default is "NC contact", and an
over limit error occurs.
WUME-GM1PG-01
Direction
Forward
Reverse
Forward
Reverse
9.2 Operation at Over Limit Input
Limit status
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Operation
Not executable, Error
occurs.
Not executable, Error
occurs.
Not executable, Error
occurs.
Not executable, Error
occurs.
Stop, Error occurs.
Stop, Error occurs.
9-5