F174_Pulseoutput_Datatable, Data Table Control - Panasonic FPS Series User Manual

Table of Contents

Advertisement

High-Speed Counter and Pulse Output

7.4.3.6 F174_PulseOutput_DataTable, Data Table Control

This instruction performs rectangular control according to the parameters in the specified DUT
with an arbitrary number of different speeds and target values. Pulses are output from the
specified channel when the control flag for this channel is FALSE and the execution condition
is TRUE.
Pulse output characteristics
f [Hz]
5000
2500
1000
0
1000 3000
1
2
x
Elapsed value of high-speed counter
Execution condition
1
Pulse output control flag
2
Pulses are output at the specified frequency until the target value is reached. Then the
frequency changes to the second frequency value and pulse output continues until the
second target value is reached, and so forth.
Pulse output stops when the last target value is reached.
REFERENCE
Please refer to the FPWIN Pro online help for details and a programming
example.