Panasonic FPS Series User Manual page 251

Table of Contents

Advertisement

Communication
Operation mode relays
For PLC link 0: R9070 to R907F (correspond to station nos. 1 to 16)
For PLC link 1: R9090 to R909F (correspond to station nos. 1 to 16)
The operation modes (RUN/PROG) can be checked for any given PLC.
Relay no.
Station no.
R9070
1
R9071
2
R9072
3
R9073
4
R9074
5
R9075
6
R9076
7
R9077
8
R9078
9
R9079
10
R907A
11
R907B
12
R907C
13
R907D
14
R907E
15
R907F
16
PLC link transmission error relay R9050
This relay turns to TRUE if a problem is detected during transmission.
Relay no.
Station no.
R9050
1–16
234
System variable name
sys_bIsPlcLink0Station1InRunMode
sys_bIsPlcLink0Station2InRunMode
sys_bIsPlcLink0Station3InRunMode
sys_bIsPlcLink0Station4InRunMode
sys_bIsPlcLink0Station5InRunMode
sys_bIsPlcLink0Station6InRunMode
sys_bIsPlcLink0Station7InRunMode
sys_bIsPlcLink0Station8InRunMode
sys_bIsPlcLink0Station9InRunMode
sys_bIsPlcLink0Station10InRunMode
sys_bIsPlcLink0Station11InRunMode
sys_bIsPlcLink0Station12InRunMode
sys_bIsPlcLink0Station13InRunMode
sys_bIsPlcLink0Station14InRunMode
sys_bIsPlcLink0Station15InRunMode
sys_bIsPlcLink0Station16InRunMode
System variable name
sys_bIsPlcLink0TransmissionError
FPΣ User's Manual
Conditions for TRUE/FALSE
TRUE:
• if the unit is in RUN mode
FALSE:
• if the unit is in PROG mode
Conditions for TRUE/FALSE
TRUE:
• if a transmission error has
occurred in the PLC link, or
• if an error has occurred in the
setting of the PLC link area
FALSE:
• if there are no transmission
errors