Panasonic FPS Series User Manual page 298

Table of Contents

Advertisement

FPΣ User's Manual
Channel used
High-speed counter
1-phase
CH0
CH1
CH2
X
X
X
X
3)
X
3)
X
3)
X
3)
X
3)
X
3)
X
CH:
Channel
X:
Available
1)
If the two channels are not used simultaneously, the maximum output frequency for each axis is 100kHz.
2)
This value applies when neither the PLC link mode nor periodic interrupts are used.
3)
When using channel 0 for pulse output, do not use reset input X2 for channel 0 and channel 1 of the high-
speed counter.
When using channel 2 for pulse output, do not use reset input X5 for channel 2 and channel 3 of the high-
speed counter.
2-phase
CH3
CH0
CH2
X
3)
X
3)
X
X
X
X
X
3)
X
3)
X
3)
X
3)
X
3)
X
3)
X
Pulse output
No interpol.
Inter
pol.
CH0
CH2
X
X
X
X
X
X
X
1)
1)
X
X
X
X
X
X
X
X
Lin.
Lin.
Lin.
Lin.
Lin.
Circ.
Circ.
Circ.
Circ.
12.2 Performance Specifications
Maximum output frequency [kHz]
High-speed
Pulse output
counter
1-
2-
No
phase
phase
interpol.
20
15
30
100
30
60
20
45
20
30
15
45
20
15
30
60
20
45
20
45
20
30
20
20
20
20
20
20
Interpol.
2)
100
80
60
60
45
20
20
20
20
281