Servo Amplifier Standard Specifications - Mitsubishi Electric MELSERVO-J2-Super Series Instruction Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION

1.2 Servo amplifier standard specifications

MR-J2S- -S084
Item
Voltage/frequency
Permissible voltage fluctuation
Permissible frequency fluctuation
Power supply capacity
Inrush current
System
Dynamic brake
Protective functions
Operational
specifications
Position command
Point table
input
number
Speed command
input
input
System
Operational
Position
specifications
command
Position command
data input
input
(when 2
Speed command
stations
input
are
occupied)
System
Point table
Automatic
operation
Automatic continuous
mode
operation
Manual
operation
Jog
mode
POINT
Refer to Section 3.1 for the specifications of the CC-Link communication
functions.
Servo amplifier
10CP
20CP
3-phase 200 to 230VAC, 50/60Hz
or 1-phase 230VAC, 50/60Hz
3-phase 200 to 230VAC:
170 to 253VAC
1-phase 230VAC: 207 to 253VAC
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic
thermal relay), servo motor overheat protection, encoder error protection, regenerative
brake error protection, undervoltage, instantaneous power failure protection, overspeed
protection, excessive error protection
Positioning by specifying the point table No. (31 points)
Set in point table. 1-point feed length setting range: 1[ m] to 999.999[mm]
Set in point table. Acceleration/deceleration time is set in point table.
S-pattern acceleration/deceleration time constant is set in parameter No.14.
Signed absolute value command system, incremental value command system, signed
absolute value command/incremental value command specifying system
Remote register setting is used for positioning.
Remote register is used to set position command data.
Feed length input setting range: 1 m to 999.999m
Remote register is used to make selection from point table.
Remote register is used to set speed command data (speed).
S-pattern acceleration/deceleration time constant is set in parameter No.14.
Signed absolute value command system, incremental value command system, signed
absolute value command/incremental value command specifying system
Point table number input, position data input system
Positioning operation is performed once in accordance with the position and speed
commands.
Varied speed operation (2 to 31 speeds), automatic continuous positioning operation (2 to
31 points)
Jog operation is performed in accordance with the parameter-set speed command by
contact input or through CC-Link communication function.
40CP
60CP
70CP 100CP 200CP 350CP 500CP 700CP 10CP1 20CP1 40CP1
3-phase 200 to 230VAC, 50/60Hz
3-phase 170 to 253VAC
Within 5%
Refer to Section14.2
Refer to Section 14.5
Sine-wave PWM control, current control system
1 - 7
Built-in
1-phase 100 to
120VAC 50/60Hz
1-phase
85 to 127VAC