1. FUNCTIONS AND CONFIGURATION
(1) Operation using CC-Link communication functions
(a) Operation
All signals can be controlled by CC-Link communication. Also, each point table setting, point table
selection, parameter value change, setting, monitor, servo motor operation and others can be
performed.
(b) Configuration
Power supply
Power supply
Option unit
Servo amplifier
MR-J2S-T01
(Axis 1)
CN10
CN1A
CN2 CN3
CN30
CN40
Servo motor
Option unit
Servo amplifier
MR-J2S-T01
(Axis 2)
CN10
CN1A
CN2 CN3
CN30
CN40
Servo motor
1 - 5
PLC CC-Link
master unit
To the next axis