Servo Amplifier Standard Specifications - Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual

Servo amplifier
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION

1.2 Servo amplifier standard specifications

Servo Amplifier
Item
Voltage/frequency
Permissible voltage fluctuation
Permissible frequency
fluctuation
Power supply capacity
Inrush current
Voltage,
frequency
Permissible
voltage
fluctuation
Control circuit
Permissible
power supply
frequency
fluctuation
Input
Inrush current
Voltage,
Interface power
frequency
supply
Power supply
capacity
Control System
Dynamic brake
Protective functions
Operational
specifications
Position
Point table
command input
number
Speed
input
command input
System
Operational
specifications
Position
Position
command
command input
data input
(when 2
Speed
stations are
command input
occupied)
System
Point table
Automatic
Automatic
operation
mode
continuous
operation
Manual
operation
Jog
mode
10T 20T 40T 60T 70T 100T 200T 350T 500T 700T 11KT 15KT 22KT 10T1 20T1 40T1
MR-J3-
3-phase or 1-phase 200
to 230VAC, 50/60Hz
3-phase or 1-phase 200
to 230VAC: 170 to
253VAC
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal relay),
servo motor overheat protection, encoder error protection, regenerative brake error protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Positioning by specifying the point table No. (255 points)
Set in point table. 1-point feed length setting range: 1[ m] to 999.999[mm]
Set in point table. Acceleration/deceleration time is set in point table.
S-pattern acceleration/deceleration time constant is set in parameter No. PC13.
Signed absolute value command system, incremental value command system, signed absolute
value command/incremental value command specifying system
Remote register setting is used for positioning.
Remote register is used to set position command data.
Feed length input setting range: 1 m to 999.999m
Remote register is used to make selection from point table.
Remote register is used to set speed command data (speed).
S-pattern acceleration/deceleration time constant is set in parameter No. PC13.
Signed absolute value command system, incremental value command system, signed absolute
value command/incremental value command specifying system
Point table number input, position data input system
Positioning operation is performed once in accordance with the position and speed commands.
Varied speed operation (2 to 255 speeds), automatic continuous positioning operation (2 to 255
points)
Jog operation is performed in accordance with the parameter-set speed command by contact input
or through CC-Link communication function.
3-phase 200 to 230VAC, 50/60Hz
3-phase 170 to 253VAC
Within 5%
Refer to section 13.2
Refer to section 13.5
1-phase 200 to 230VAC, 50/60Hz
1-phase 170 to 253VAC
Within 5%
30W
Refer to section 13.5
DC24V 10%
(Note 1) 150mA or more
Sine-wave PWM control, current control system
Built-in
1 - 7
1-phase 100V to
120VAC, 50/60Hz
1-phase 85 to
132VAC
1-phase 100 to
120VAC, 50/60Hz
1-phase 85 to
132VAC
45W
30W
External option
Built-in

Advertisement

Table of Contents
loading

Table of Contents