Mitsubishi Electric MELSERVO-J2-Super Series Instruction Manual page 148

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

5. OPERATION
1) Absolute value command specifying system
This system is an auxiliary function for point tables to perform automatic operation by
specifying the absolute value command or incremental value command.
Positioning in single direction
The operation example given below assumes that the set values are as indicated in the
following table. Here, the point table No. 1 uses the absolute value command system, the point
table No. 2 the incremental value command system, the point table No. 3 the absolute position
system, and the point table No. 4 the incremental value command system.
Point table
Position data
STM
No.
[ 10
m]
1
5.00
2
3.00
3
10.00
4
6.00
Note: 1. Always set "0".
2. Always set "0" or "2" to the auxiliary function of the last point table among the consecutive point tables.
0: When point table is used in absolute value command system
1: When point table is used in incremental value command system
Acceleration time constant
of point table No. 1 (100)
Servo motor speed
Position address
Selected point table No.
ON
Forward rotation start
(RYn1)
OFF
Point No. out put
(RX(n+2)2 to RX(n+2)6)
Servo motor
Acceleration time constant
speed [r/min]
3000
2000
1000
500
Forward
Speed
rotation
(3000)
0
0
Deceleration time constant
[ms]
100
Invalid
Invalid
Invalid
Deceleration time constant
of point table No. 1 (150)
Speed
(1000)
Speed
(2000)
3.00
5.00
8.00
1
5 - 13
Dwell [ms]
[ms]
(Note 1)
150
0
Invalid
0
Invalid
0
Invalid
0
6.00
10.00
Auxiliary
function
1
3
1
0 (Note 2)
Speed (500)
16.00
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents