CIP Training Pro C5200 series
Adjustment Settings for Operators
054: [Additional Fusing Temp 1]
Adjust the fusing unit's accumulated temperature for a specific time after a job starts.
Depending on the operating environment, the fusing temperature may drop before paper is transferred
to the fusing unit. Use this function to prevent the fusing temperature dropping.
Fusing temperature must be adjusted if a fusing error or abnormal luster occurs after three to ten pages
Setting Items
[Additional Fusing Temp 1]
055: [Additional Fusing Temp 2]
Adjust the fusing unit's accumulated temperature for a specific time after writing starts.
Depending on the operating environment, the fusing temperature may drop before paper is transferred
to the fusing unit. Use this function to prevent the fusing temperature dropping.
Fusing temperature must be adjusted if a fusing error or abnormal luster occurs after three to ten pages
Setting Items
[Additional Fusing Temp 2]
056: [Cleaning Web Rotation Interval]
Specify the interval between each activation of the cleaning web.
wear out twice as fast, which makes it necessary to replace the cleaning web more often.
Setting Items
057: [Cleaning Web Contact Position]
Specify the cleaning web separation behavior during printing.