138 en | Maintenance
Notice!
All transponder information is supported for the export and import of ".dat" files, except RSSI
Offset and Area data.
Data fields in required
order
#Transponder ID
Coordinator ID
Transponder Name
IP Connected
Coordinator
IP Address
Port Number
Comm Port Index
Ignore Communications
Failure
Isolate For Location
Trouble Text
Tamper Text
Trouble Response
2019.08 | V2.18.1.6 | DOC
Excel Column Restrictions
A
1-255. This field should contain only numeric
ASCII characters.
B
Reserved for future use, this field should contain
only the numeric 0.
C
This field may be up to 24 characters. This field
may contain any printable ASCII character
except the '?'
D
"0 RS232", "1 TCP IP". This field should contain
only numeric ASCII characters.
E
0. Reserved for future use, this field should
contain only the numeric "0".
F
This field is blank if IP Connected is 0 (RS232).
This field should contain a valid IP address if IP
Connected is 1 (TCP IP).
G
This field is blank if IP Connected is 0 (RS232).
This field should contain only numeric ASCII
characters, 1-65535.
H
This field used only if IP Connected is 0
(RS232). "0 A", "1 B", "2 C", "3 D", "4 E", "5 F",
"6 G", "7 H", "8 I", "9 J", "10 K", "11 L"
I
This field is 0 if this is not selected. This field is
1 if this is selected. This field should contain
only numeric ASCII characters.
J
This field is 0 if this is not selected. This field is
1 if this is selected. This field should contain
only numeric ASCII characters.
K
This field may be up to 40 characters. This field
may contain any printable ASCII character
except the '?'.
L
This field may be up to 40 characters. This field
may contain any printable ASCII character
except the '?'.
M
This field may be up to 135 characters. This field
may contain any printable ASCII character
except the '?'
Technical Reference Manual
Security Escort
Bosch Security Systems B.V.