Security Escort
Character limit
Pages per call
Pager group
Baud rate
System name
System phone
Send installer demo
alarms
Send all other alarms
Security Pager Confm
Not Reqd
Cancel page If alarm
reset
Send page a second
time, 2 minute delay
Do not resend alarm
page
Modem init
[Save]
Bosch Security Systems B.V.
This is the maximum number of characters allowed per page.
Typically, this is set to 80 characters. The Security Escort System will
truncate the pager message at this number of characters. The paging
company assigns this value.
This is the maximum number of pager messages allowed per phone
call. Typically, this is set to 4 pages per call. When this number of
messages have been sent, and there are more messages to be
delivered; the Security Escort System will hang up and redial the
paging service to deliver the remaining messages. The paging
company assigns this value.
This is the group of up to 8 pagers that this message is to be sent to.
You may program the individual pager as well as a group of pagers.
The pager group will be sent the page before the individual.
This is the baud rate that will be used to communicate with the paging
computers. The paging company assigns this value.
This identifies the Security Escort System when multiple Security
Escort Systems report to the same service pager. Keep this field as
short as reasonably possible since these characters, including space
character, will be sent before each trouble message and they are
included in the Character limit set above. If not desired, leave blank.
This will present phone number to be called in response to the service
page. Only use if required since these characters, plus a space, will be
sent before each trouble message. They are included with the System
name in the Character limit set above. If not desired, leave blank.
If checked, demo alarms will be sent to the security pager.
If checked, all actual alarms will be sent to the security pager.
If checked, the confirmation pager message is not sent to the security
pager when the alarm is acknowledged by an acknowledgement
transmitter.
If checked, the alarm page will be canceled if the alarm is reset before
it can be communicated to the paging service.
If checked an alarm page will be sent a second time to the security
pager. Do this in case the pager was in an area where pages could not
be heard when the first page was sent.
If checked, a pager message is sent to the security person only once
till the alarm is cancelled or acknowledged.
This is the initialization string sent to the modem to set it up for pager
communications. Normally, this setting would not have to be changed.
To allow changes to this string, hold down the <Shift> + <Ctrl> keys
when this dialog is first opened. This string is specific to each modem
model. The default setting should work with most modems.
Save the changes and close the dialog window.