Eclipse 500 System Manual page 96

Hide thumbs Also See for 500:
Table of Contents

Advertisement

Section 5. Oxygen
5.5.4 Oxygen Service Panel
An oxygen service panel is located on the left side of the nose. The service panel
contains an analog pressure gauge. The normal servicing range of 1550 to 1850 psi
is indicated by a green band. Low pressure (0 to 300 psi) is indicated by an amber
band. Overpressure (above 1850 psi) is indicated by a red band.
Instrument
Oxygen Pressure (psi)
5.5.5 Cockpit Oxygen Gauge
Oxygen bottle pressure can also be read on a gauge on the left switch panel. The
caution range and maximum limit pressures are indicated differently than the exterior
service panel gauge. A low oxygen pressure of 0-200 psi is indicated in RED, while
overpressure, >1850 psi is indicated in amber. Normal operating range, 200-1850 psi
is green.
Instrument
Oxygen Pressure (psi)
76
Figure 49. Oxygen Service Panel
Caution Range (Yellow)
0-300 psi
Caution Range (Red)
0-200 psi
Copyright © — Eclipse Aviation Corporation
Eclipse 5OO Systems Manual
Normal Range (Green)
1,550-1,850 psi
Normal Range (Green)
200-1,850 psi
Version 2.0 April 2007
Max. Limit (Red)
1,850 psi – Full Scale
Max. Limit (Yellow)
1,850 psi – Full Scale