Section 8. Engines & Fire Protection
8.4.10 Fuel Flow
Fuel flow is continuously displayed on the MFD with a digital readout in pounds per
hour (PPH) and with a white moving tape and digital readout on the engine synoptic
page. The scale of the tape is 0-800 PPH. An adjacent tape displays fuel flow range,
with a green band extending from 60 PPH to the top of the tape. There are no amber
or red bands.
8.4.11 Oil Pressure
Version 2.0 April 2007
Figure 101. Fuel Flow Displays- Digital and Tape
Figure 102. Oil Pressure Displays- Digital and Tape