8.4.9 N2 RPM
N
is continuously displayed on the MFD with a digital readout in percent of maximum
2
RPM and with a moving tape and digital readout on the engine synoptic page. The
scale of the tape is 0 to 105%. An adjacent tape displays N
the limit tape extends from 45% to 100%. An amber band extends from 100% to
102%. A red band begins at the maximum continuous limit of 102%.
The digital value and moving tape are white for N
for N
values in the amber band, and in red for N
2
RPM exceeds the limit for 20 seconds, a L (R) ENG EXCEEDANCE warning
message appears
156
Figure 100. N2 Displays- Digital and Tape
Copyright © — Eclipse Aviation Corporation
Eclipse 5OO Systems Manual
limits. A green band on
2
values in the green band, in amber
2
values above the RPM limit. If the