Section 14. Primary Flight Display (PFD)
Audio Page (AUDIO)
The AUDIO page provides control and setting for all communication and
navigation systems with an audio output. Each pilot can tune and change
each audio source volume level via this page.
Exiting the Composite Mode
The only way to exit the Composite Mode is with the keyboard
1. Press L PFD or R PFD
2. Press PFD COMPOSITE
NOTE:
If both keyboards are inoperative, any PFD in the Composite Mode remains
in the Composite Mode for the duration of the flight.
Composite Mode Lockout
To avoid conflicting commands, only one user interface is active at one time. If
the left PFD is in composite mode with the MFD working, system functions
normally controlled through the MFD are locked out. If only the right PFD is in
composite mode with the MFD working, functions are locked out on the MFD. If
both PFDs are in composite mode, system functions can be controlled only
through the left PFD.
Crew Alerting System (CAS) Message Display
To provide similar functionality for CAS message acknowledgement on a PFD
operating in composite mode, an alert prompt appears in the R5 line select key,
any time a new caution or warning level message appears.