Eclipse 500 System Manual page 378

Hide thumbs Also See for 500:
Table of Contents

Advertisement

Section 15. Multi Function Display (MFD)
Oil pressure is continuously displayed on the MFD with a digital readout and with a
moving tape and digital readout on the ENG synoptic page. Oil pressure is displayed
on a normalized scale from 0 to 10 rather than in PSI.
An adjacent tape displays oil pressure limits. Operating limits in PSI change with N2
RPM. However, this is transparent to the pilot. The color bands display constant
limits regardless of the engine RPM.
When oil pressure is in the normal (green band) range the moving tape and digital
value are white. If the oil pressure is in the caution (amber bands) range (either high
or low), the tape and digital value are amber. If the oil pressure is above 9 or below
1, the tape and digital value are red, and a L(R) OIL PRESSURE HIGH or L (R) OIL
PRESSURE LOW caution appears.
The amber bands and the lower red band incorporate a time delay for transient
conditions. For oil pressures outside the green range, the oil pressure value and
tape are amber for a period of time. If the exceedance continues, the oil
pressure value and tape turn red.
Oil Pressure
9.1-10
358
Time Delay for Amber Display
8.1-9
1-1.9
90 seconds
0-0.9
10 seconds