Setting the Trigger Mode

Both the mode for the read trigger input from the TRIG input terminal and the Read Mode can
be set.
l System Set./Trigger Mode
1.
Make the settings for each item.
2.
Select OK.
Item
Trigger Mode
Read Timeout
The Trigger Mode Setting is valid only for the TRIG input terminal.
The trigger from the Console is always a one-shot trigger.
Selections
One Shot
One reading is performed synchronized on the rising edge (OFF to
(default)
ON transition) of the trigger signal. If reading is successful, reading
is ended and the reading results is output.
The trigger signal is also synchronized as the camera shutter input
to enable taking images of moving workpieces in an accurate posi-
tion.
Continuous
Reading is perform continuously as long as the trigger signal is ON.
Level
Reading is repeated until successful while the trigger signal is ON.
If reading is not performed successfully, NG is output when the trig-
ger signal turns OFF.
1 to 99
Set the timeout period.
(default: 99)
The timeout period is the period from input of the trigger until read-
ing is forced to end.
System Settings
Trigger Mode
Trigger Mode
: One Shot
Read Timeout
: [
]sec
99
Read Mode
:Normal
OK
Cancel
Description
SECTION 5
V530-R2000
43
User's Manual