Executes Teaching - Omron V530-R2000 User Manual

2d code reader (fixed)
Table of Contents

Advertisement

SECTION 7
Host Communications
@RD
Function
Input
Output
@GT
Function
Input
Output
V530-R2000
68
User's Manual
Outputs the current read data. (POLLING command)
This command is used to resend data lost due to communications errors
or to have data sent for multidrop connections.
@ R
D
Communications Alarm Output for Analytical Functions Is OFF
· Reading Successful or Alarm Generated
Read data
· When Reading Fails
N G Error code
?
Communications Alarm Output for Analytical Functions Is ON
· Reading Successful
O K
Read data
· When Reading Fails
N G Error code
?
· When an Alarm Is Generated by the Condition Watcher
A L
Read data

Executes teaching.

Read condition
@ G T
Specify 0 to 9 for the read condition number.
If the read condition number is omitted, the current read condition
number will be overwritten.
When Teaching Was Successful:
G
T
O
K
When Teaching Failed:
G
T
N
G

Advertisement

Table of Contents
loading

Table of Contents