Setting Communications Conditions - Omron V530-R2000 User Manual

2d code reader (fixed)
Table of Contents

Advertisement

SECTION 5
System Settings

Setting Communications Conditions

The conditions for communicating between the Controller and the host can be set.
Make these settings according to the communications specifications of the host.
l System Set./Com Condition
1.
Make the settings for each item.
2.
Select OK.
Item
Baud Rate
Data Length
Parity Bit
Stop Bit
Baud rates over 20 kbps are not defined for the RS-232C standard. Depending on the cable length,
communications may not be stable if 38400 bps or higher is set. If there are problems, set the baud
rate to 19200 bps or lower.
Use the following settings when executing a Backup, Upload, or similar command (CB, CU, etc.)
Data length
Parity
Stop bits
V530-R2000
42
User's Manual
Selections
2400 bps, 4800 bps, 9600 bps,
19200 bps, 38400 bps (default),
57600 bps, 115200 bps
7bit, 8bit (default)
None (default), Odd, Even
1 bit (default), 2 bit
Item
Setting
8 bits
None
1 bit
Com Condition
Baud Rate
: 38400bps
Data Length
: 8bit
Parity Bit
: None
Stop Bit
: 1bit
OK
Cancel
Description