Omron V530-R2000 User Manual page 54

2d code reader (fixed)
Table of Contents

Advertisement

Condition Watcher
The Condition Watcher monitors transitions in continuous reading. If the monitor level
falls, and alarm signal is output so that decreases in the ability to read can be detected
in advance.
Condition Watcher
Light
1
1000
5
ALM
6
OMRON2002
GL
7
GL
No.
Display item
1
Appraisal item
2
Point
3
Graph
4
Accumulative reading
information
5
Read status and com-
ment
6
Read data
7
Communications con-
tents
Point 24
500
Make lighting brighter
OMRON2002
C
R
OMRON2002
C
R
Select the appraisal item to display on the screen.
The display will change as follows then the Up/Down Keys are pressed:
Light, Focus, Mark, Locate, None.
Meaning of Appraisal Items p.36
Displays the quality points of the appraisal item selected at (1).
Displays the transitions in the total points for the most recent 1,000 readings.
The most recent readings are displayed on the right. The graph scrolls left.
Displays the totals of the results of reading.
Total: Number of readings, OK: Number of successful readings
Alarm: Number of alarms, NG: Number of failures
OK, NG, or ALM is displayed.
If ALM is displayed, a comment will be displayed to indicate the cause or
solution.
Displays the data that was read.
Displays the contents of the last two communications with the host. The
most recent command is shown on top.
This information enables checking the serial interface and the communica-
tions status of the input terminals.
The following is displayed as the communications contents: "Trig-in" indi-
cates a trigger from the input terminal and "Trig-con" indicates a trigger from
the Console. All other displays are commands.
Setting Read Conditions
Still
2
100
50
3
0
Total
1635
OK
1632
4
Alarm
30
NG
3
Description
SECTION 4
V530-R2000
37
User's Manual