Omron V530-R2000 User Manual page 99

2d code reader (fixed)
Table of Contents

Advertisement

SECTION 7
Host Communications
n Example of Host Link Connection to PLC
This example describes a connection to a CS1H PLC made by OMRON.
§ Settings at the PLC
Set the communications conditions of the Host Link Unit of the PLC or the Host Link
port built into the CPU Unit. For details on setting methods, refer to the manual for the
PLC.
Communications method Host Link
Unit number
Baud rate
Data length
Parity bit
Stop bits
§ Settings at the Controller
Communications
mode
p.40
Communications
conditions
p.42
V530-R2000
82
User's Manual
Item
Setting
01
9600 bps
7 bits
EVEN
2 bits
Item
Communications mode
Interface
Read Area
Begin read word
Write Area
Begin Write Word
PLC Mode Check
Baud rate
Data length
Parity bit
Stop bits
Setting
Host Link
RS-232C
DM
0100
DM
0110
ON
The same settings as those at the PLC.