PREFIX
n Ambient Temperature
• Maintain a minimum clearance of 50 mm above and
below the V530-R2000 to improve air circulation.
• Do not install the V530-R2000 immediately above
significant heat sources, such as heaters, trans-
formers, or large-capacity resistors.
• Do not let the ambient operating temperature
exceed 50 ° C (122 ° F).
• Provide a forced-air fan or air conditioning if the
ambient temperature is near 50 ° C (122 ° F) so that
the ambient temperature never exceeds 50 ° C (122 ° F).
n Noise Resistance
• Do not install the V530-R2000 in a cabinet contain-
ing high-voltage equipment.
• Do not install the V530-R2000 within 200 mm of
power cables.
V530-R2000
x
User's Manual
Control box
Controller
Louver
Power cable
200 mm min.
200 mm min.
Controller