Omron V530-R2000 User Manual page 107

2d code reader (fixed)
Table of Contents

Advertisement

SECTION 7
Host Communications
Timing Charts
n One-shot Triggers
One reading is performed synchronized on the rising edge (OFF to ON transition) of the
trigger signal in the I/O terminals. If reading is successful, reading is ended and the
reading results is output.
The trigger signal is also synchronized as the camera shutter input to enable taking
images of moving workpieces in an accurate position.
RUN
TRIG
BUSY
NG
ALARM
RS-232C
/422
V530-R2000
90
User's Manual
Read Screen
entered.
OFF
ON
OFF
ON
OFF
ON
Reading performed.
OFF
ON
OFF
ON
*The output time to RS-232C/422 changes depending on the data volume and baud rate.
Reading performed.
Reading NG
Reading OK
NG
Read
data
Read Screen
exited.
Reading performed.
Reading OK
Alarm output
Read
data