Accumulator (AC) object

This object handles the total amount of electrical energy.
Property list
The following table lists available properties for the AnalogOutput object.
Additionally, the availability of reading/writing data from/to a BACnet device is shown in the following table.
R: Read-only, W: Read/Write
PropertyID
Property
36
EventState
65
MaxPresValue
75
ObjectIdentifier
77
ObjectName
79
ObjectType
81
OutOfService
85
PresentValue
103
Reliability
111
StatusFlags
117
Units
187
Scale
190
Value_Before_Change
191
Value_Set
192
Value_Change_Time
371
PropertyList
*1 The PresentValue property cannot be set to a value greater than the value of the MaxPresValue property (PropertyID: 65). Change the
value of the MaxPresValue property according to the maximum value to be set for the PresentValue property.
Reliability=2(OverRange) if Reliability is 0 when PresentValue changes from within the range of MaxPresValue to out of the range of
MaxPresValue.
Reliability=0(NoFaultDetected) if Reliability is 2 when PresentValue changes from out of the range of MaxPresValue to within the range
of MaxPresValue.
When Reliability is other than the above, the value of Reliability does not change. The same applies when OutOfService changes from
TRUE to FALSE and the buffer memory is updated.
(Reliability=1 remains if Reliability is 1 when PresentValue changes from within the range of MaxPresValue to out of the range of
MaxPresValue (or reverse order).)
*2 Only ANSI/ASHRAE Standard 135-2016 and ANSI/ASHRAE Standard 135-2012 are supported.
4 FUNCTIONS
30
4.2 BACnet Object Function
*1
*2
Data type
Enumerated
Unsigned
BACnetObjectIdentifier
CharacterString
Enumerated
BOOLEAN
Unsigned
Enumerated
BitString
Enumerated
BACnetScale
Unsigned
Unsigned
BACnetDateTime
BACnetARRAY[N]ofBACnetPropertyIdenti
fier
R/W
Description
R
Indicates the event status.
R
Indicates the maximum value of
PresentValue.
R
Indicates the ID to identify the object.
R
Indicates the object name.
R
Indicates the object type.
W
Indicates whether the device is
disconnected from the physical input.
W
Indicates the number of count of input
pulses.
R
Indicates reliability.
R
Indicates the object status.
R
Indicates the unit.
R
Indicates the coefficient for conversion to
the value indicated by the unit.
R
Indicates the value of the previous
PresentValue when the PresentValue was
changed by writing a value to Value_Set.
W
PresentValue can be changed by writing a
value.
R
Indicates the date and time when the
PresentValue is changed by writing a
value to Value_Set.
R
Indicates the property list.