Field Service Ver. 1.0 Feb. 2006
ADJUSTMENT/SETTING
4.
MECHANICAL ADJUSTMENT
4.1
Leading Edge Skew Adjustment
[2]
1. Load the test chart [1] in the DF and
[1]
make one 1-sided copy five consecutive
times.
16eaf3c001na
2. Fold each of the sample copies as illus-
trated and check for any deviation.
Specifications: 0 ± 3.0 mm
3. If the deviation does not fall within the
specified range, perform the following
adjustment procedure.
16eaf3c002na
4. Open the DF.
5. Loosen the decorative screw [2] and the
nut [3] in the back to the right.
[3]
16eaf3c003na
6. If there is a deviation as shown on the
figure, turn the screw counterclockwise
to adjust it.
16eaf3c004na
4. MECHANICAL ADJUSTMENT