Mechanical Adjustment; Adjusting Skew Feed - Konica Minolta DF-612 Service Manual

Option printer
Table of Contents

Advertisement

6. Mechanical adjustment

6.
Mechanical adjustment
6.1

Adjusting skew feed

X
Deviation in + (plus)
Y
Deviation in + (plus)
40
X
Deviation in - (minus)
9J07F3C513DA
[1]
A0EYF3C500DA
Y
Deviation in - (minus)
9J07F3C514DA
Service Manual
Field Service Ver. 1.0 Jun. 2008
1. Check how the edges of the chart
are misaligned.
The amount of the deviation of the
chart will be X.
2. Place the chart [1] in the document
feed tray (with the side having an
arrow facing up).
3. Make copies 5 times repeatedly in
single side mode.
4. Fold all 5 sample copies as illus-
trated and check for any deviation.
Deviation on the sample will be Y.
5. Obtain the difference between the
deviation of the chart and the devia-
tion of the sample.
Difference of the deviation = Y - X
Specifications: 0 ± 2 mm
6. If the difference of the deviation does
not fall within the specified range,
perform the following adjustment.
Y109850-7