No.
Display element/operator control
(4)
"Overload trip class" selector switch
(5)
"Overload protection function" test
button
(6)
Actuator
(7a)
Connection point for auxiliary switch
block (direction of rotation 1)
(7b)
Connection point for auxiliary switch
block (direction of rotation 2)
(8)
Control circuit terminals
(9)
Main circuit terminals
(10)
"Device status" display
(11)
"Main contacts closed" display
(12)
"Group error" display
(13)
"Short-circuit protection function"
test button
(14)
"Malfunction" mechanical display
(15)
"Main contacts closed" LED display
(direction of rotation 1)
(16)
"Main contacts closed" LED display
(direction of rotation 2)
(17)
Warning notice
(18)
Interface for connecting cable
(input)
(19)
Interface for connecting cable
(output)
You can find information on the device statuses in " Diagnostics (Page 87)".
1)
You can find information on the terminal block pin assignments in "Connecting the
2)
3RA64/3RA65 compact starter with IO-Link (Page 134)".
You can find information on the external auxiliary switch block in "External auxiliary switch
3)
block (Page 156)".
Reference to "Parameter "Operation at Preset <> Actual Configuration" (Page 115)".
4)
SIRIUS 3RA6 compact starter
System Manual, 08/2018, NEB560060102000/RS-AB/007
Marking
Description
CLASS 10/20
For selecting the overload trip class 10E or 20E.
TEST
Press this button for at least 5 secs to test the overload
protection function.
OFF
•
•
READY
•
•
TRIPPED
TRIPPED: Short circuit or malfunction.
•
•
—
You can plug an auxiliary switch block for direction of
rotation 1 into the connection point.
—
You can plug an auxiliary switch block for direction of
rotation 2 into the connection point.
L+, C/Q, L-
Connection terminals for IO-Link and
A2-, A1+/Y1, Y2
auxiliary voltage and limit switch (direction of
Y3, Y4
rotation 1)
limit switch (directon of rotation 2).
1L1, 3L2, 5L3
Connection terminals and main conductor on the line
2T1, 4T2, 6T3
side and outgoing side.
DEVICE
Read the device status of the compact starter:
Device OK
•
Overload, process mapping error, general warning,
•
etc.
PRESET configuration not equal to ACTUAL
•
configuration
STATE ON I
The LED indicates whether the main contacts are open
or closed.
SF
The LED indicates whether a group error is present.
TEST I>>
Press this button to test the short-circuit protection
function.
RLT 0%
Indicates either that the compact starter is in order or
there is a malfunction.
1
The LED indicates whether direction of rotation 1 has
DO 0.0
been triggered.
2
The LED indicates whether direction of rotation 2 has
DO 0.1
been triggered.
—
—
—
—
—
—
3RA64/3RA65 compact starter with IO-Link
6.2 Description of the hardware
OFF: Compact starter is out of service.
READY: Compact starter is ready.
2)
1)
1)
4)
1)
1)
1)
1)
1)
1)
1)
3)
3)
2)
1)
99