7.14 Operator panel for 3RA64/3RA65 compact starter with IO-Link
Note
Resetting to automatic mode!
If you remove the enabling block from the operator panel or the connecting cable between
the operator panel and the starter while in manual mode, the compact starter switches to the
safe state and the "DEVICE" LED flashes yellow.
For this reason, reset the compact starter to automatic mode before removing the enabling
block or the connection cable.
Note
If manual mode is activated for a starter while it is in continuous mode and you select a
different starter on the operator panel, the first starter will remain in continuous mode.
Machine start-up!
If you reset the operator panel to automatic mode while an ON command is simultaneously
pending via the IO-Link, the compact starter switches back on immediately and the
machine starts up. People may be injured if they stay in the danger area of the machine.
Make sure that the danger area of the machine is kept clear of people.