6.4.4.2
Parameter "Operation at Preset <> Actual Configuration"
The "Operation at Preset <> Actual Configuration" parameter sets the severity level of the
test for the "Operator panel available" parameter.
The table below shows the values for the "Operation at Preset <> Actual Configuration"
parameter.
Table 6- 5
Value
0
1
If the parameter value "Operation at Preset <> Actual Configuration" is set to "disable",
operation of the compact starters is only possible if the parameter setting "Operator panel
available" is fulfilled precisely.
If the parameter value "Operation at Preset <> Actual Configuration" is set to "enable",
operation of the compact starters is possible via IO-Link regardless of whether or not an
operator panel is connected.
The following table shows the effects of the sample parameter values set:
Table 6- 6
Set parameter values
"Operator panel
available" = "Yes" and
"Operation at Preset <>
Actual Configuration =
"disable"
The parameter "Operation at Preset <> Actual Configuration" can only be modified via
IO-Link. It cannot be adjusted at the device.
SIRIUS 3RA6 compact starter
System Manual, 08/2018, NEB560060102000/RS-AB/007
Parameter "Operation at Preset <> Actual Configuration"
Description
Operation at Preset <> Actual Configuration: disable
Operation at Preset <> Actual Configuration: enable
Parameter setting - example of operation with operator panel
Practical implementation
Operator panel
available
Operation of the
compact starter
possible.
3RA64/3RA65 compact starter with IO-Link
Default setting
enabled
Operator panel not
available
Operation of the
compact starters not
possible.
6.4 Parameters
Operator panel is
disconnected during
operation
The compact starter
shuts down. Further
operation of the device
is not possible.