Table 3-1 Descriptions of Basic Functions (continued)
Function key
Access key
[Frequency
[Frequency
Set center frequency equal to frequency
marker
center
marker
marker difference.
frequency]
Soft menus for the measurement of time
spectrum, adjacent channel power, channel
——
MEAS
power, and occupied bandwidth pop up.
[Measurement
MEAS
Disable all measurement functions.
off]
Open or close time spectrum measurement
[Time spectrum]
MEAS
mode.
On Off
[Adjacent
Soft menu for measuring adjacent channel
MEAS
channel power]
power of transmitter pops up.
On Off
[Channel
Enter soft menu of channel power
MEAS
power]
measurement.
On Off
[Occupied
Enter soft menu of occupied bandwidth
bandwidth]
MEAS
measurement.
On Off
Measurement setup menu, used for the
[Measurement
MEAS
measurement of adjacent channel power,
setu
]
channel power and occupied bandwidth.
[Measurement
[Channel
Power displayed by integral, and return back
setu
bandwidth]
to bandwidth .
[Spacing
[Measurement
Spacing between center frequencies of main
between
setu
channel and adjacent channel.
channels ]
[The number of
adjacent channel]
Descriptions
measuremen
[Output power]
[Normalization]
[Frequency
discrimination
tes
Set the number of upper adjacent channels
[Measurement
and lower adjacent channels for adjacent
setu
channel power measurement.
[Measurement
[Occupied
Calculate power of occupied bandwidth
setu
power]
between two frequency markers.
MODE
——
Soft menu of other measurement functions
[Tracking
Soft menu related with the setting of tracking
MODE
sourc
source pop up.
[Tracking
[Tracking
Enable or disable tracking source
source]
sourc
measurement function.
On Off
[Output
[Tracking
Used to set output power of tracking source
power]
sourc
[Network
[Tracking
Soft menu about tracking source network
sourc
measurement function pops up.
[Network
[Network
Enable or disable network measurement
measurement]
measuremen
function.
On Off
[Network
Set output power of signal source at time of
measuremen
network measurement.
[Network
[Reference
Set reference level of network measurement.
measuremen
level]
[Network
Network measurement users conduct
measuremen
normalization calibration on the spot.
Soft menu about frequency discrimination test
MODE
functions pops up.
27