Linear Vibration Welder 5000 Series
Valve Calibration
Figure 6-37 Calibration - Valve
Valve calibration needs to be carried out by the maintenance
personnel or manufacturer's service technicians after the
valve is replaced.
PSI Feedback:
The hydraulic pressure feedback read
from the analogue input card.
System Force:
The force of the hydraulic system at
any given moment.
Offset Force:
The force required to move the lift table
and the lower tool.
Hold Force:
The force used during the hold time.
Force Across Part:
parts. (System Force - Offset Force).
Page 82
User's Manual
This feature is for use by
servicing personnel only.
The actual force applied to the
Dukane Manual Part No. 403-589-01