Linear Vibration Welder 5000 Series
Hydraulic Safety
The hydraulic system is self-contained. It normally
operates at between 1,000 and 1,200 psi. It is however
capable of operating up to 1,500 psi. It is unsafe to
attempt to bypass the interlocks and operate the welder
with the rear service doors open. The interlocks are
located at the top of the electrical and hydraulic service
doors. Figure 2-9 shows a door interlock device and the
mating receptacle in the cabinet.
The vibration welder may be shipped with the hydraulic
fluid reservoir full or drained, depending on whether the
destination is local or international. Before operating the
welder, hydraulic fluid must be added to the reservoir if
it is empty. This is covered in Section 3 – Installation,
Hydraulic Drive.
Page 14
User's Manual
Figure 2-8
Figure 2-9
Hydraulic Cabinet
Service Doors
Cooling Air
Outlet
Pneumatic
Lockout
Cooling
Air Inlet
Rear Hydraulic Service Doors
WARNING
Never operate the vibra-
tion welder with any of
the service doors open.
This is an unsafe practice
and can result in injury
or death.
The rear service doors
also serve as acoustic
shields.