Calibration Sequence
1. Remove the tool before calibrating.
Use Table Up/Down touch keys to control the table.
2. Raise the table until it stops.
3. Press the accept button and the right opti-touch.
4. Lower the table until it stops.
5. Press the accept button and the right opti-touch.
Voltage Delay
Allow 1 to 3 seconds for the PLC to detect normal operating
voltage before the Voltage Overload alarm is triggered.
Current Delay
Allows 1 to 3 seconds for the PLC to detect normal operating
current before Current Overload alarm is triggered.
Feedback Delay
Allows 1 to 3 seconds for the PLC to detect a feedback
signal, before No Feedback Detected alarm is triggered.
Input
Raw –
Transducer output value being
read from the analog input card.
Volts –
Transducer output voltage.
Dukane Manual Part No. 403-589-01