Figure 6-26 Setup Mode - Setting Limits
Upper and Lower Limits
The limits section of the screen deals with setting upper and
lower suspect part limits for some main welding variables:
Time, Total Collapse (Distance), Amplitude and Force.
When each weld cycle is finished, the welder compares
actual returned values with the programmed limits. If the
values equal or exceed the limits, the part is considered
suspect.
Setting the Limits:
1. Touch the entry box for the value to be entered, and
the virtual keypad appears allowing the user to make
a numerical entry.
2. Continue entering values in the entry boxes for both
upper and lower limits until finished.
Dukane Manual Part No. 403-589-01
NOTE
Any limit set to zero will be ignored. Any
combination of upper and lower limits or
no limits are possible. The value of an
upper limit must always be greater than
the value of a lower limit.
Section 6 - Touch Screen
Page 67