VALVES
In Figure 6-31 on the previous page Valve 1 is shown as an
active valve. The valve is programmed to extend at CYCLE
START, and it will retract AT START OF HOLD. Table 6-I
shows the selection possibilities for Extend and for Retract
CONFIGURABLE I/O
Valves and Valve Sensors Status
The tables below provide a key to the status symbols used
with the valves and valve sensors..
Valve
Status
Table 6-II
Each valve is paired with
extend and retract sensors.
Dukane Manual Part No. 403-589-01
Valve disabled
.(dark gray)
Valve enabled.
(light gray)
Valve extending
(green).
Valve retracting
(green).
Valve Status
NOTE
Extend
OFF - Disabled
AT CYCLE START
AT DOOR CLOSED
AT TABLE HOME
AT EJECT
AT START OF WELD
PART LOCATORS
(only on valve 1)
Table 6-I
Valve Extend, Retract Selections
Sensor disabled
(dark gray)
Sensor enabled
(light gray)
Valve
Status
Output ON
(yellow)
Sensor ON
(green)
Table 6-III
Valve Sensor Status
Section 6 - Touch Screen
Retract
AT START OF HOLD
AT END OF HOLD
AT TABLE HOME
AT DOOR OPEN
AT START OF WELD
Page 73