Linear Vibration Welder 5000 Series
E E-STOP Reset
Pressing the button enables the operator to reset the welder
when it is initially turned on or to clear an aborted cycle
caused by:
1. Pushing the
EMERGENCY STOP
2. Opening the rear service doors.
3. Required reset on initial power up.
F Hydraulic Pump On
(light/switch)
The hydraulic system is turned on by pushing in the green
button. When the hydraulic pump is activated, the switch
is illuminated green. When the hydraulics are off, the
green button is dark. The lift table cannot be moved if
the hydraulics are off. This is a push-on only switch. The
hydraulic pump is turned off by:
1. Pushing the EMERGENCY STOP button in.
2. Opening the rear service doors.
3. Turning off the AC power
G E-STOP
(button)
E-STOP
The
button on the control panel is shown in
Figure 4-1. The left mounting box contains an emergency
(E-STOP)
stop
button next to the left
as shown in Figure 4-2. Both of these switches function
the same, and pressing either switch stops the weld cycle
and freezes the lift table in its current position.
Both emergency stop buttons must be in their reset
position before the lift table can be lowered and the welder
restarted.
Page 28
User's Manual
(button)
(E-STOP) button.
OPERATE
switch
NOTE
Follow the instructions shown in the
message area at the top of the touch
screen.
Dukane Manual Part No. 403-589-01