Linear Vibration Welder 5000 Series
Figure 6-32 Test Valves Pop-up Window
Stanchion Detect
When enabled, detects when the stanchions are extended.
If so, the weld cycle will not operate. Stanchions need to
be retracted to run a weld cycle.
Buttons on the pop-up window allow the operator to test
for proper valve operation. Each valve can be tested for
its functions - to extend and to retract. When a button is
pushed, it activates a function of the valve, and the button's
virtual LED changes from red to green. See the valve status
explanation that follows.
Page 76
User's Manual
Save Setup
Touch the
to save the current setup.
Reload Setup
Touch the
button to reload data to the
current setup.
File Control
Touch the
to open the File Control pop-up
window.
Test Valves
Touch the
and the Test Valves pop-up
window appears as shown
below.
button
button
button