Page 1
User’s Manual Dukane Part No. 403 – 577– 01 Dukane Intelligent Assembly Solutions • 2900 Dukane Drive St. • Charles, Illinois 60174 USA • TEL (630) 797- 4900 • FAX (630) 797- 4949 ISO 9001:2000 Products are manufactured in ISO www.dukane.com/us...
Page 2
Printed in the United States of America. Part Number: 403–577–01 This ultrasonic equipment is manufactured under one or more of the following U.S. Patents: 3,780,926 3,825,481 4,131,505 4,277,710 5,798,599 5,880,580 6,984,921, 7,225,965, and 7,475,801 Page ii Dukane Manual Part No. 403-577-01...
Revision History Revision Revision Number Summary Date - 00 Original release. 08/01/2008 - 01 Add 20kHz and 30kHz models. 11/12/2009 Update Pop-up Fault Status Screens. Add Trigger by Power feature. Add Options section. Dukane Manual Part No. 403-577-00 Page iii...
Page 4
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page iv Dukane Manual Part No. 403-577-01...
(e.g. –I, –II, –III). As an ex- ample, Figure 3–2 would be the second illustration in section three while Table 3–II would be the second table in section three. Condition Hearing Electrical or Practice Protection Hazard Page 3 Dukane Manual Part No. 403-577-01...
Linear Ramp Soft Start circuitry allows the acous- and assures you of manufacturing excellence. tic stack to ramp up to operating amplitude smoothly, minimizing the start-up surges and abnormal stress to the stack and generator. • Digi-Trac Tuning tracks the resonant frequency of the Page 4 Dukane Manual Part No. 403-577-01...
Labor about the particular type of plastic(s) you are using. When plastic materials are being processed, they may emit fumes and/or gases that could be hazardous. Make sure you have adequate ventilation whenever these plastics are processed. Page 7 Dukane Manual Part No. 403-577-01...
It must be plugged ulations concerning proper wiring and grounding. into a grounded receptacle. Do not use a two-wire exten- sion cord with this product. Page Dukane Manual Part No. 403-577-01...
Figure 3-1 on the following See Connecting Cables on the next page. page. CAUTION If you have any questions about the grounding of your equipment and/or the electri- cal box, contact a qualified electrician. Page 11 Dukane Manual Part No. 403-577-01...
Power Cord Strain Relief HAND PROBE HAND PROBE OUTPUTS OUTPUTS Optional Connections REAR VIEW REAR VIEW 100/12O VOLT MODEL 200/24O VOLT MODEL Figure 3-1 Generator Detail - Rear Views Page 1 Dukane Manual Part No. 403-577-01...
Page 19
AC voltage. At high power levels there is high current, and the cable must be securely attached to the hand probe for safe operation. Only use original equipment ultrasound cables for safe and reliable system operation. Page 13 Dukane Manual Part No. 403-577-01...
ENTER is pressed if in a non-latching fault mode. It is active until ENTER is pressed if in a latching fault mode. NOTE Refer to Figure 9-1, OUTPUTS Inter- face Example, Page 65. Page 14 Dukane Manual Part No. 403-577-01...
Do NOT re- peatedly try to reset the circuit breaker. If it trips, this will only cause more damage to the Continued generator. Page 17 Dukane Manual Part No. 403-577-01...
Page 24
“back” key. Press this key when you do not want to horn should never come in store the selection in memory. direct contact with a metal fix- ture or anvil when ultrasound is activated. Page 1 Dukane Manual Part No. 403-577-01...
After all connections have been completed. Push OFF 1. Push the Power Switch to ON (Figure 4-2). The generator performs a self-diagnostics sequence. Figure 4-2 Power Switch Current DUKANE Setup 2. The Power-up screen appears briefly - Figure 4-3. Software iQ Hand Probe Setup #1...
(trigger) is pressed. Status Indication Stack Frequency IN CYCLE Frequency: 40087 Hz Power: 25 W Power Draw Power Bar Graph % Figure 4-5 Example of an In Cycle Screen Page 0 Dukane Manual Part No. 403-577-01 ...
U/S is activated. When the programmed energy is reached, U/S stops. The trigger switch must be held activated for the entire welding cycle. Then it is released so that a new weld cycle can begin. Dukane Manual Part No. 403-577-01 Page 3...
Figure 5-4 Time Weld Mode - 2 Setup #1Empty Load Defaults? Select YES to load the default operating mode which is Manual, and you can weld using the Manual mode. Page 4 Dukane Manual Part No. 403-577-01 ...
The time can not be set below 0.001 second. Use the and the keys to move the cursor Figure 5-8 Energy Weld Mode - 2 and to set the digits for the time you want. Hit E Hit C See Figure 5-8. Dukane Manual Part No. 403-577-01 Page 5...
Press the AMP key. The screen will appear as in 100 % Figure 5-10. Set the amplitude level using the keys and the keys. Figure 5-10 Amplitude Press ENTER to confirm your amplitude setting. Page Dukane Manual Part No. 403-577-01 ...
Figure 5-11: Figure 5-11 INFO Screen Using the keys, move the pointer to indicate: System Information, Hardware Settings, or Advanced Settings Dukane Corporation Press ENTER to make the selection. iQ 20kHz Hand Probe FP v1.07 MB v2.56 System Information FPGA v6 Manufacturer’s information is shown including the...
Before you change a setting, please check of this unit! with Dukane personnel for their recommendations. Figure 5-13 Warning Screen The warning screen is shown for a few seconds, then, the Advanced Settings screen appears.
For an explanation of Trigger by Power and the three settings that are connected with it, please refer to Application Note 506 found on our website at: http://www.dukane.com/us/DL_ApplData.asp When Trigger by Power is selected, three additional settings screens are presented: Trigger By Power •...
T: 0.000 S A: 100% E: 0 J H: 0.0 S Select YES or NO, and press ENTER again. Figure 5-22 Setup Maintenance - 4 Continued Page 30 Dukane Manual Part No. 403-577-01 ...
Press ENTER, and a pop-up screen will ask you to confirm your selection. Make your choice, and press ENTER. Check that the setup is deleted. Press SETUP, and the Setup Maintenance screen will show EMPTY for the setup you just deleted. Dukane Manual Part No. 403-577-01 Page 31...
Page 38
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Dukane Manual Part No. 403-577-01 Page 3 ...
Typical Horn Less Tip Trigger Rear View Pistol-style Grip Models 41HP40 & 41HP40S Trigger Actuator Compressed Air Fitting Hanger Strain Relief U/S Cable Hand Grip Typical Horn Less Tip Rear View Figure 6-1 Typical Hand Held Probes Dukane Manual Part No. 403-577-01 Page 35...
Replaceable tips are not commonly used in high–volume production environments. Standard Custom Horn Horn Figure 6–2 Hand Probe, Horn and Tip Dukane Manual Part No. 403-577-01 Page 3 ...
Figure 6–3. This is commonly referred to as a stack. As indicated, the components are secured with threaded studs. Horn Figure 6–3 Probe, Booster and Horn Dukane Manual Part No. 403-577-01 Page 37...
Replaceable Tips to Horn NOTE inch-lb ft-lb Size Dukane Part No. for the 20kHz span- 40.7 1/2” x 20 tpi tip threads ner wrenches is 721–68. 3/8” x 24 tpi tip threads 33.9 5/16” x 24 tpi tip threads Dukane Part No.
This is shown in Figure 6-6. NEVER thread a stud into the transducer or the output end of the booster first. See Booster Notes in this section for correctly identifying the output end of a booster. Dukane Manual Part No. 403-577-01 Page 3...
1. Inspect all surfaces to be joined for stress cracks, chips, or gouges. Any of these irregularities will affect operation and could lead to further equipment damage. Contact the Dukane Ultrasonic Tooling Department CAUTION concerning a damaged booster.
47.5 20 kHz stack Do not tighten the studs to these higher 24.4 30 kHz stack ratings as it may induce unnecessary 24.4 40 kHz stack stress in the assembly. Table 6-III Horn/Booster Torque Unit Conversions Dukane Manual Part No. 403-577-01 Page 41...
PROBE ASSEMBLY Spanner Mounting Stud Wrench (Insert Into Horn Holes First and Tighten to Torque Specs) Input End HORN HORN ISASSEMBLY Figure 6–6 Hand Probe Assembly and Disassembly Dukane Manual Part No. 403-577-01 Page 4 ...
(on horns with wrench flats) to provide an opposite force to keep the Figure 6–8 Removing a Replaceable Tip from the horn from turning in your hand. Refer to Figure 6–8 for the Horn correct tip removal procedure. Dukane Manual Part No. 403-577-01 Page 43...
1.0 (e.g. 0.6), it is a reducing or reverse booster. A neutral booster has no gain and has 1.0 stamped on it. A neutral or coupling booster is used to provide another probe stack clamping location for added stability. Dukane Manual Part No. 403-577-01 Page 44 ...
Generator Fault Does Not Reset a fault. When a system fault condition does not automatically reset, the generator needs servicing. System Power Diagnostic Procedures The only fault indications available with these probe systems are the ones shown on the LCD display. Page 47 Dukane Manual Part No. 403-577-01...
The horn amplitude may not be uniform if it has been machined, altered or damaged. All of these will change the resonant frequency of the horn. You can have the horn analyzed. Dukane Manual Part No. 403-577-01 Page 4 ...
Fault will reset when system cools down. Over Temperature Internal communications error. Generator Fault Turn generator power off and back on. Cycle Power Call Dukane service if the fault persists. Table 7- I Pop-Up Fault Status Screens - Manual Mode Continued Page 4...
Page 56
Process Fault Input Undervoltage Energy Not Reached Enter Clears Fault Table 7-II Pop-Up Fault Status Screens - Time and Energy Modes Dukane Manual Part No. 403-577-01 Page 50 ...
Section 8 – Options SECTION 8 Options iQ Hand Probe Buzzer Kit ......53 iQ Hand Probe Foot Switch Kit .....53 Page 51 Dukane Manual Part No. 403-577-01...
Page 58
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page 5 Dukane Manual Part No. 403-577-01...
Page 59
This kit allows the customer to add their own external foot switch to replace the trigger on the hand probe. An external breakout box with cabling is supplied. The box connects to the generator and to the hand probe. Page 53 Dukane Manual Part No. 403-577-01...
Page 60
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page 54 Dukane Manual Part No. 403-577-01...
5% to 95% non–condensing @ +5°C to +30°C Nonoperating storage guidelines: Temperature: - 4°F to 158°F (-20°C to +70°C) Air Particulates: Keep the equipment dry. Minimize exposure to moisture, dust, dirt, smoke and mold. Humidity: 5% to 95% non–condensing @ 0°C to +30°C Page 5 Dukane Manual Part No. 403-577-01...
T h e E M C D i r e c t i v e 2 0 0 4 / 1 0 8 / E C for Heavy Industrial — EN 61000-6-4: 2001 EN 55011: 2003 EN 61000-6-2: 2001 EN61000–4–2 EN61000–4–3 EN61000–4–4 EN61000–4–5 EN61000–4–6 EN61000–4–8 EN61000–4–11 • The Low Voltage Directive 2006/95/EC. • The Machine Directive 98/37/EC. EN 60204-1: 2006 S afety of Machinery - Electrical Equip- m ent of Machines Part 1: Specification f or General Requirements. Effective 12/29/09: The Machinery Directive 2006/42/EC. EN 60204: 2006 S afety of Machinery - Electrical Equipment of Machines Part 1: General Requirements. Page 1 Dukane Manual Part No. 403-577-01...
Page 68
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page Dukane Manual Part No. 403-577-01...
Page 70
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page 4 Dukane Manual Part No. 403-577-01...
Page 71
Provided by Customer Power Supply NOTE + 30 VDC Maximum To OUTPUTS: + 24 V (Output 1, 2, or 3 Common) Status connected Indicator or Audible Chassis Alarm Ground (333mA (Earth). maximum) Figure 10-1 OUTPUTS Connection Example Page 5 Dukane Manual Part No. 403-577-01...
Page 72
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page Dukane Manual Part No. 403-577-01...
Section 11 – Contacting Dukane Contacting Dukane Identify Equipment When contacting Dukane about a service–related problem, be prepared to give the following information: • Model number, line voltage and serial number • Fault/error indicators from the LCD display • Software version (Press .
Page 76
Series, Ultrasonic Hand Held Systems User’s Manual This page intentionally left blank Page 70 Dukane Manual Part No. 403-577-01...
Horn/Booster Torque Unit Conversions ................41 Pop-up Fault Status Screens - Manual Mode ..............49 7-II Pop-up Fault Status Screens - Time and Energy Modes ..........50 AC Power Requirements ....................60 Page 74 Dukane Manual Part No. 403-574-01...
Page 81
By passing its audit, Dukane can assure traditional inspection–oriented quality system you that we have in place a well–defined and...
Page 82
Series, Ultrasonic Hand Held Systems User's Manual www.dukane.com/us Part No. 403 – 577– 01 Printed in the United States of America Dukane Intelligent Assembly Solutions • 2900 Dukane Drive St. • Charles, Illinois 60174 USA • TEL (630) 797- 4900 • FAX (630) 797- 4949...