Planet IGS-5225 Series User Manual page 197

L2+ ring managed gigabit ethernet switch
Hide thumbs Also See for IGS-5225 Series:
Table of Contents

Advertisement

Max Age
• Maximum Hop Count
Transmit Hold Count
Advanced Settings
Object
Edge Port BPDU
Filtering
Edge Port BPDU Guard
• Port Error Recovery
Port Error Recovery
Timeout
The Industrial Managed Switch implements the Rapid Spanning Protocol as the default spanning
tree protocol. When selecting "Compatibles" mode, the system uses the RSTP (802.1w) to be
compatible and to co-work with another STP (802.1D)'s BPDU control packet.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
-Minimum:
The higher of 4 or [(Max. Message Age / 2) + 1]
-Maximum:
30
The maximum age of the information transmitted by the Bridge when it is the
Root Bridge. Valid values are in the range 6 to 40 seconds.
-Default:
20
-Minimum:
The higher of 6 or [2 x (Hello Time + 1)].
-Maximum:
The lower of 40 or [2 x (Forward Delay -1)]
This defines the initial value of remaining Hops for MSTI information generated at
the boundary of an MSTI region. It defines how many bridges a root bridge can
distribute its BPDU information. Valid values are in the range 6 to 40 hops.
The number of BPDU's a bridge port can send per second. When exceeded,
transmission of the next BPDU will be delayed. Valid values are in the range 1 to
10 BPDU's per second.
Description
Control whether a port explicitly configured as Edge will transmit and receive
BPDUs.
Control whether a port explicitly configured as Edge will disable itself upon
reception of a BPDU. The port will enter the error-disabled state, and will be
removed from the active topology.
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
The time that has to pass before a port in the error-disabled state can be
enabled. Valid values are between 30 and 86400 seconds (24 hours).
197
User's Manual of IGS-5225 series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents