Functions
7.12 3RW5 HMI High Feature
Parameter
Parameter
Load communication and HMI parameters to
soft starter
Load communication and HMI parameters to
micro SD card
Device change
Save logbooks to micro SD card
Save service data to micro SD card
FW update
Download language
Memory space
158
Soft starter
Communication module
HMI
Complete memory
Free memory
Used memory
Description
The parameters of the communication and the
3RW5 HMI High Feature are transferred from the micro SD card to
the 3RW50 soft starter. The following data is transferred:
Device parameters of the 3RW5 HMI High Feature
Communication parameters
The parameters of the communication and the
3RW5 HMI High Feature are transferred from the
3RW50 soft starter to the micro SD card. The data is saved in an
automatically generated folder. The following data is transferred:
Device parameters of the 3RW5 HMI High Feature
Communication parameters
When a device is replaced, the configuration data and
communication parameters can be transferred to the new device.
The following data is transferred:
Device-related information (Page 151) for the
3RW50 soft starter:
Tag function
Tag location
Additional information
Device parameters of the 3RW5 HMI High Feature
Communication parameters
The logbooks are backed up on the micro SD card. For more
information, see Chapter Logbooks (Page 183).
The 3RW50 soft starter records service data during starting and
stopping. If problems occur in the system in conjunction with the
3RW50 soft starter, you can save the service data on the
micro SD card and have them evaluated by the service personnel.
This action is only possible when the motor is switched off.
The firmware update is carried out if a valid firmware file is stored
on the micro SD card. The 3RW5 HMI High Feature automatically
detects which firmware file the micro SD card contains
The firmware update is documented in the device logbook
(Page 183).
You can find more information on the firmware update in Chapter
Performing firmware update with micro SD card
(3RW5 HMI High Feature) (Page 188).
An additional language is loaded onto the 3
RW5 HMI High Feature. For more information, see Chapter
Reloading a language for the High Feature 3RW5 HMI
(Page 159).
The memory capacity is displayed.