Summary of Triggering Capabilities

Because logic analyzer triggering provides a great deal of functionality,
the following table provides a brief summary of the capabilities covered
in this article. Each of these capabilities will be described.
Summary of Logic Analyzer Triggering Capabilities
Capability
=====================
Edges
---------------------
Boolean expressions
---------------------
Ranges
---------------------
Storage qualification
---------------------
Counters
---------------------
Timers
---------------------
Next: "Sequence Levels" on page 194

Sequence Levels

While logic analyzer triggers are often simple, they can require
complex programming. For example, you may want to trigger on the
rising edge of one signal that is followed by the rising edge of another
signal. This means that the logic analyzer must first find the first rising
194
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Trigger point
------------------------------
Examples
===============================================
If there is rising edge on SIG1 then Trigger
If there is falling edge on SIG1 then Trigger
-----------------------------------------------
If ADDR = 1000 and DATA = 2000
-----------------------------------------------
If ADDR in range 1000 to 2000
-----------------------------------------------
1. If..
Else If ADDR in range 1000 to 2000 then
Store Sample
Go to 1
Else If ADDR not in range 1000 to 2000 then
Don't Store Sample
Go to 1
-----------------------------------------------
1. If DATA = 1000 Then
Increment Counter 1
Go to 2
2. If Counter 1 > 2 Then
Trigger
-----------------------------------------------
1. If DATA = 1000 Then
Start Timer 1
Go to 2
2. If Timer 1 > 500 ns Then
Trigger
-----------------------------------------------