The Trigger Tab
they are specified. The logic analyzer executes the set of actions in the
"then" clause associated with the first listed "if" or "else if" clause that
becomes true.
• Advanced - 4-way branch
Like the 3-way branch, but with 3 "Else if" clauses.
• Advanced - pattern1 AND pattern2
Searches for two different patterns occurring in the same sample. If you
set it to look for more than 1 occurrence, you can specify whether
occurrences are consecutive or not. You can also add other events,
including labels, to be searched for.
• Advanced - pattern1 OR pattern2
Finds either pattern1 or pattern2 or both in a sample. If you set it to look
for more than 1 occurrence, you can specify whether the occurrences are
consecutive or not. You can also add other events, including labels, to be
searched for.
See Also
"Editing Advanced Trigger Functions" on page 78 for more information on
using the advanced trigger functions.

Settings Subtab

Sample Period
Acquisition
Depth
154
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(Timing mode only). Lets you specify how often the the
logic analyzer samples signals from the device under test.
Lets you use a smaller portion of the acquisition memory
and speed up processing of the captured data.