The autotest result summary screen

Chapter 5
After the autotest completes, the Autotest Summary screen appears. Examples of
passing and failing tests are presented below.
In the case of a failing test, if the calculate fault location option is turned on, the
WireScope 350 will automatically calculate the distance to the most likely
failure source in the tested cable run.
Measured length of cabling run
Wiremap diagram
Limit icon (Category 6)
Test configuration icon (Basic Link)
Summary margins
Failure location and pairs involved
are marked in red.
Distance to fault show n next to
tape measure icon.
Failing margins show n in red.