Step 2. Choose The Sampling Mode - Agilent Technologies 16718A Help Volume

Logic analyzer
Table of Contents

Advertisement

Chapter 1: Getting Started

Step 2. Choose the sampling mode

Step 2. Choose the sampling mode

There are two logic analyzer sampling modes to choose from: timing
mode and state mode.
In timing mode, the logic analyzer samples asynchronously, based on
an internal sampling clock signal.
In state mode, the logic analyzer samples synchronously, based on a
sampling clock signal (or signals) from the device under test. Typically,
the signal used for sampling in state mode is a state machine or
microprocessor clock signal.
To choose the sampling mode
1. In the Sampling tab, choose Timing Mode or State Mode.
14
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

16716a

Table of Contents