Furuno FSS-3BB Installation Manual page 31

Fish species and biomass sounder
Hide thumbs Also See for FSS-3BB:
Table of Contents

Advertisement

How to extend the control unit cable
To extend the length of the cable between the trackball control unit and the processor
unit, use the optional cable assembly (6TPSH-XH12X2-LxxSP2, 5/10 m).
1. Unfasten four binding screws (M3×8) from the bottom of the unit, and a pan head
screw (M3×8) and flat washer from the back of the unit to remove the cover.
Note: Remove the cover slowly to prevent damage to the cables connected to the
circuit board in the unit.
Binding screw (M3×8, 4 pcs)
Control unit cover
2. Remove the cable clamp from the trackball control unit, then disconnect the con-
trol unit cable from J1.
Binding screw
Cable clamp
3. Pull out the control unit cable from the cover.
4. Pass the optional cable assembly (6TPSH-XH12X2-LxxSP2) through the cable
hole on the cover.
J1
Disconnect this connector.
Cable assy
(6TPSH-XH12X2-LxxSP2)
Pan head screw (M3×8)
Flat washer
Control unit
cable
2. WIRING
2-11