12. Click the
button for [Time Setting] to open the
[Time Setting] window, then enter the appropriate
time manually and click the [OK] button.
13. Select the appropriate time zone from the [Time
Zone] pull-down list.
14. Select [HF] from the menu on the left-hand side of the window.
Sounder
Transducer Setting
HF
LF
15. Set up the HF (high frequency) transducer, referring to the following table.
Menu item
[Connection]
Set the presence of the transducer connection ([Connected]/[Not
Connected]). When [Connected] is selected, set up the following
menu items.
[XDCR Select]
Select the setting method of the transducer.
• [TD-ID]: When a TD-ID transducer is connected.
• [Model]: Select the transducer model.
• [Manual]: Manually input the transducer information.
Note: For the [Model] and [Manual] setting, it may be necessary to
apply an offset to fish size (length) if the calculated and actual fish
sizes are different, to get accurate data for the fish size histogram.
For details of the [Fish Size] menu see the operator's manual.
[Freq (Model)]
Select the central frequency of the transducer (38, 50, 107 or 200
kHz). This menu item is enabled when [XDCR Select] is set to [Mod-
el]. If [TD-ID] is selected, the frequency is automatically entered.
[Transducer]
Select the model number of the transducer. This menu item is en-
abled when [XDCR Select] is set to [Model]. If [TD-ID] is selected,
the model number is automatically entered.
[TX Power]
The TX power of the transducer automatically appears according to
the model number. The setting is fixed. The value is shown only
when [XDCR Select] is set to [Model] or [TD-ID].
[Freq (Manual)]
Manually set the frequency of the transducer (setting range: 15 to
200 kHz). This menu item is enabled when [XDCR Select] is set to
[Manual].
[Voltage]
Set the transmission voltage of the transducer (unit: V). The setting
range depends on the setting value for [Freq (Manual)]. This menu
item is enabled when [XDCR Select] is set to [Manual]. If [TD-ID] or
[Model] is selected, the voltage is automatically entered and the set-
ting is fixed.
[Band Width]
Set the band width of the transducer (unit: kHz). The setting range
depends on the setting value for [Freq (Manual)]. This menu item is
enabled when [XDCR Select] is set to [Manual].
Transducer Setting : HF
Connection
Not Connected
XDCR Select
Freq(Model)
Transducer
TX Power
Freq(Manual)
Voltage
Band Width
Description
3. INITIAL SETTINGS
Time Setting
OK
Cancel
Save/Exit